logo
Aperçu ProduitsCable solaire

Photovoltaic PV Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V

Certificat
Chine Zhongdong Cable Co., Ltd. certifications
Chine Zhongdong Cable Co., Ltd. certifications
Je suis en ligne une discussion en ligne

Photovoltaic PV Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V

Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V
Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V

Image Grand :  Photovoltaic PV Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V

Détails sur le produit:
Place of Origin: Hebei,China
Nom de marque: Zhongdong
Certification: CCC,IEC,VDE,TUV,ISO
Model Number: H1Z2Z2-K
Conditions de paiement et expédition:
Minimum Order Quantity: Negotiable
Prix: Négociable
Packaging Details: woodern drum
Delivery Time: 10work days
Payment Terms: L/C,T/T
Supply Ability: 500KM/Week

Photovoltaic PV Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V

description de
Jacket: Halogen free flame retardant sheath material for solar cables Conductor Material: Class 5 Tinned copper
Application: Solar Farm Core: 1 Core
Colour: Black /red colours available on request Voltage: 1500V

Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V


APPLICATION

  1. Renewable Energy Systems

    Widely used in photovoltaic power plants for connecting solar panels to inverters

    Suitable for both rooftop and ground-mounted solar arrays due to its UV-resistant properties


  2. Industrial Automation

    Deployed in control cabinets for motor connections in manufacturing lines

    Used as trailing cables in cranes and robotic systems (flexible variant available)


  3. Infrastructure Projects

    Approved for underground installations in commercial buildings (tested to 90°C)

    Common in tunnel lighting systems where halogen-free properties are required


  4. Specialized Environments

    Marine applications due to its oil-resistant sheath (oil-resistant variant H1Z2Z2-KO)

    Mining equipment connections with enhanced mechanical protection


CONSTRUCTION

Conductor:Class 5 tinned copper conductors 

Insulation:Halogen free flame-retardant insulation material for solar cables 

Outer sheath:Halogen free flame retardant sheath material for solar cables


Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V 0


Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V 1

STANDARD 


EN50618:2014


CHARACTERISTIC  


  • AC Voltage Rating Uo/U:1.0/1.0kV 
  • DC Voltage Rating Uo/U:1.5kV
  • Maximum operating temperature of conductor:+120
  • Operating ambient temperature: -40℃~+90
  • Cable laying temperature:Not less than -25
  • Minimum Bending Radius: Single core:6D (D is the actual outer diameter of the cable)


SPCIFICATION


Cross section(mm²)

Conductor Construction(no/mm)

Conductor Stranded OD.max(mm)

Cable OD.(mm)

Approximate weight of cable
kg/km

Max Conductor Resistance(Ω/km,20°C)

1×1.5

48/0.20

1.58

4.8

35

13.7

1×2.5

77/0.20

2.02

5.2

47

8.21

1×4

56/0.285

2.46

5.7

64

5.09

1×6

84/0.285

3.01

6.3

86

3.39

1×10

77/0.40

4.1

7.2

128

1.95

1×16

7×17/0.40

5.5

8.9

196

1.24

1×25

7×27/0.40

6.7

10.7

299

0.795

1×35

7×38/0.40

8.2

12.4

407

0.565

1×50

19×20/0.40

10.0

14.6

571

0.393

1×70

19×28/0.40

11.6

16.4

773

0.277

1×95

19×38/0.40

13.5

18.5

1024

0.210

1×120

24×38/0.40

14.4

19.8

1266

0.164

1×150

30×38/0.40

16.2

22.2

1584

0.132

1×185

37×38/0.40

18.2

25.0

1967

0.108

1×240

48×38/0.40

20.6

27.8

2518

0.0817


FACTORY


Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V 2


PROJECT


Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V 3


PACKAGE


Photovoltaic PV  Solar DC Cable H1Z2Z2-K 1.5~240mm² 1500V 4


FAQ

Q‌: What is the H1Z2Z2-K cable used for?

A: It is a ‌solar photovoltaic cable‌ designed for DC power transmission in solar systems, connecting panels to inverters or junction boxes

Q: What standards does H1Z2Z2-K comply with?

A:Complies with ‌EN 50618:2014‌ (European standard) and often carries ‌TUV/CE certifications‌ for safety and performance

Q‌: What conductor material is used?

A: Features ‌5-class stranded tinned copper wire‌ for low resistance and corrosion resistance

Q‌: What is the maximum operating temperature?

A: 120℃‌ for conductors and ‌90℃‌ for ambient use, with short-term tolerance up to ‌200℃‌ (5 seconds)

Q‌: What insulation and sheath materials are used?

A: Cross-linked polyethylene (XLPO)‌ insulation and sheath, offering ‌flame-retardant, halogen-free, and UV-resistant‌ properties

Q‌:What is the rated voltage?

A: DC 1.5kV‌ (maximum permissible voltage: ‌1.8kV‌)

Q‌: What colors are available for the outer sheath?

A: Typically ‌black or red ‌ for polarity identification

Q‌:How is the cable installed?

A: Suitable for ‌direct burial, overhead, or conduit‌ installations due to its weatherproof design

Q: What is the lifespan of the H1Z2Z2-K cable?

A: ≥25 years‌ under normal conditions, resistant to aging and environmental stress


Coordonnées
Zhongdong Cable Co., Ltd.

Personne à contacter: Mr. Bai

Téléphone: +8619829885532

Envoyez votre demande directement à nous (0 / 3000)