logo
Aperçu ProduitsLe PVC a isolé le cable électrique

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32

Certificat
Chine Zhongdong Cable Co., Ltd. certifications
Chine Zhongdong Cable Co., Ltd. certifications
Je suis en ligne une discussion en ligne

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32
‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32

Image Grand :  ‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32

Détails sur le produit:
Lieu d'origine: Hebei , Chine
Nom de marque: Zhongdong
Certification: IEC,CE,ISO,TUV
Numéro de modèle: New-York-J
Conditions de paiement et expédition:
Quantité de commande min: Négociable
Prix: Négociable
Détails d'emballage: Rouleaux, tambours en bois, tambours en acier, moulinets ou personnalisés
Délai de livraison: 7-30 jours basés sur différentes Qté
Conditions de paiement: L / C, T / T
Capacité d'approvisionnement: 100 km / semaine

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32

description de
Tension: 0.6/ 1 kV Armoring: Non
Isolation: PVC Cœur: Multi-cœurs
Plage de température: - 30°C à + 70°C engainé: PVC

 ‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32


APPLICATION

 

This product is suitable for power transmission and distribution in lines with AC 50Hz and rated voltage not exceeding 0.6/1kV.


CONSTRUCTION

 

  • Conductor: Class 1/Class 2 stranded Copper conductor
  •  Insulation: Polyvinyl chloride (PVC) 
  • Filler(options): Polypropylene mesh tearing rope 
  • Inner sheath:Polyvinyl chloride (PVC) 
  • Armour: Aluminum wire or stainless steel wire(single core)galvanized steel wire(multi core) 
  • Outer sheath: Polyvinyl chloride (PVC)

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 0‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 1

STANDARD

 

GB/T 12706.1,IEC 60502-1



CHARACTERISTIC

 

 

  • Voltage Rating:  Uo/U:0.6/1kV  Um:1.2kV
  • Maximum operating temperature of conductor:+70℃
  • Operating ambient temperature: -20℃~+45℃
  • Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
  •  Minimum Bending Radius:   Single core:15D    multi core:12D


SPECIFICATIONS

Specs
mm²

Conductor diameter
mm

Nominal  thickness of insulation
mm

Lining thickness
mm

Nominal thickness of steel wire
mm

Nominal thickness of sheath
mm

Approximate outer diameter of cable
mm

Approximate cable weight
kg/km

3×1.5

1.38

0.8

1

0.8

1.8

15.1

376

3×2.5

1.78

0.8

1

0.8

1.8

15.9

432

3×4

2.25

1

1

1.25

1.8

18.8

680

3×6

2.76

1

1

1.25

1.8

19.8

776

3×10

4

1

1

1.25

1.8

22.5

1009

3×16

5

1

1

1.25

1.8

24.6

1265

3×25

6.1

1.2

1

1.6

1.8

28.6

1855

3×35

7.2

1.2

1

1.6

1.8

31.2

2248

3×50

8.4

1.4

1

1.6

2

35.1

2835

3×70

10

1.4

1.2

2

2.1

40.2

3962

3×95

12

1.6

1.2

2

2.2

45.6

5070

3×120

13

1.6

1.2

2

2.3

47.9

5923

3×150

14.9

1.8

1.4

2.5

2.5

54.7

7676

3×185

16.5

2

1.4

2.5

2.7

59.5

9116

3×240

18.4

2.2

1.6

2.5

2.9

65.3

11289

3×300

21

2.4

1.6

2.5

3.1

72.2

13681

3×400

23.4

2.6

1.8

3.15

3.4

80.6

17764


OUR FACTORY 

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 2



PROJECTS

‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 3‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 4‌IEC 60502‌ Standard PVC Insulated Cable Steel Wire Armoured PVC Sheathed NYRY VV32 5


FAQ

Q. Where are SWA-PVC cables typically used?

A. Suitable for:

Underground direct burial (with drainage)

Industrial plants with mechanical stress

Hazardous environments (e.g., chemical exposure)

Q. How does steel wire armour enhance cable performance?

A‌. Mechanical protection‌: Resists crushing, rodent damage, and impact.

Grounding‌: Acts as an earth continuity conductor in some designs

Q. What are the temperature limits for SWA-PVC cables?

A‌. Operating range‌: -15°C to +70°C (PVC insulation)

Max conductor temperature‌: 70°C under continuous load

Q. Are SWA-PVC cables flame-retardant?

A. Standard versions comply with ‌IEC 60332-1‌ (flame propagation test). For higher requirements, choose ‌LSZH (Low Smoke Zero Halogen)‌ variant

Q.. How to calculate bending radius during installation?

A. Minimum bending radius = ‌12× cable diameter‌ to avoid armour deformation

Q.. Can SWA-PVC cables be installed in wet conditions?

A. Yes, provided the outer sheath is intact. For submerged use, ensure ‌IP68-rated joints‌ and anti-corrosion armour

Q. What standards apply to SWA-PVC cables?

A‌. International‌: IEC 60502-1

Regional‌: BS 5467 (UK), UL 4 (US)

Coordonnées
Zhongdong Cable Co., Ltd.

Personne à contacter: Mr. Bai

Téléphone: +8619829885532

Envoyez votre demande directement à nous (0 / 3000)